Doornbos Heating Air Conditioning Service Chicago

Heating and Air Conditioning Solutions.

The Doornbos team of service technicians, sheetmetal mechanics and pipefitters are the best trained in the industry - and we support them with a customer service department that cares about keeping our customers happy.
Read about the value of quality installation and service >>

Our professional standards ensure quality results - on every project Doornbos performs. From design assistance, to automated fabrication, quality installations, to testing and balancing and control systems, Doornbos guarantees satisfaction and we're available 24/7 for emergency service. Read our satisfaction guarantee.>>

Doornbos Planned Service Options:

  • Preventive Maintenance Air Conditioning
    Agreement includes the following at minimum:

    We start by sending you a fully capable serviceman, not a clean and check technician. Fully capable servicemen have a minimum of 5 years experience, continuing education and a proven track record. We do not use the less qualified clean and check technicians.

  • • Inspect filter
    • Check blower belt tension and adjust
    • Inspect blower wheel and clean if necessary
    • Inspect blower motor and oil if applicable
    • Inspect condensate drain line and clean appropriately
    • Inspect all wiring and relays
    • Inspect condenser fan motor and blade -
        oil if applicable
    • Check crankcase heater for proper operation
    • Clean condenser coil and condenser drain openings
        with water or compressed air
    • Inspect thermostat
    • Cycle air conditioning unit
    • Check for voltage drops across relays
    • Check amperage of blower motor, condenser motor
        and compressor
    • Install guages and check for adequate refrigerant
        charge using superheat or sub-cooling method
    • Check temperature drop across indoor coil to insure
        proper air flow (cleaning of indoor coil will be an
        additional charge upon approval)
    • Give a written report and recommendations of system

  • Preventive Maintenance Forced Air Heating
    Agreement includes the following at minimum:

    We start by sending you a fully capable serviceman, not a clean and check technician. Fully capable servicemen have a minimum of 5 years experience, continuing education and a proven track record. We do not use the less qualified clean and check technicians.

  • • Inspect filter
    • Check blower belt tension and adjust
    • Inspect blower wheel and clean if necessary
    • Inspect blower motor and oil if applicable
    • Remove burners, pilot assembly or flame sensor
        for cleaning
    • Inspect heat exchanger for possible cracks or rusting
        (excessive flaking or soot cleaned at an additional
        charge upon approval)
    • Inspect combustion blower motor and oil if applicable
    • Inspect all wiring, relays, integrated control boards
    • Inspect thermostat
    • Cycle heating system
    • Check for proper exhaust of flue gas
    • Check for proper voltage
    • Check amp draw of blower motor and combustion
        blower
    • Check for proper burner operation
    • Check flame signal or millivolt reading
    • Check temperature rise to insure within manufacturer
        specifications and proper air flow (cleaning of
        evaporator coil or adjustments to ductwork will be
        additional charge upon approval)
    • Check safety circuit to insure safe operation
    • Check near gas line for leaks
    • Give a written report and recommendations of system
    Note: Condensing furnaces (90%)
    • All of the above PLUS:
    • Flush condensate trap
    • Inspect exhaust and intake piping if easily accessible
    • Confirm condensate drainage during operation

  • Preventive Maintenance Boiler
    Agreement includes the following at minimum:

    We start by sending you a fully capable serviceman, not a clean and check technician. Fully capable servicemen have a minimum of 5 years experience, continuing education and a proven track record. We do not use the less qualified clean and check technicians.

  • • Inspect pressure/temperature guage
    • Inspect expansion tank and confirm air cushion.
        Drain if necessary
    • Inspect pump to incude bearing assembly, coupler,
        motor and motor mounts. Oil if applicable
    • Remove reducing valve screen and clean
    • Confirm reducing valve is operable
    • Remove burners and pilot assembly or flame sensor
        for cleaning
    • Inspect heat exchanger for water leaks and rusting
        (excessive rusting or soot cleaned at an additional
        charge upon approval)
    • Inspect near piping for water leaks
    • Inspect thermostat
    • Cycle heating system
    • Check for proper exhaust of flue gas
    • Inspect controls and wiring
    • Check for proper voltage
    • Check amp draw of water pump
    • Check for proper burner operation
    • Check millivolt reading or flame signal
    • Test electrical circuit to insure safe operation
    • Check and test water operating temperature
    • Give a written report and recommendations of system


© 2007 - 2008: Doornbos Heating and Air Conditioning, Inc.